Solutions to common failures of mobile lighting towers
The mobile lighting tower is a kind of generator set, which can be used for mobile lighting. The mobile lighting tower will also fail. The common possibility is that the engine cannot be started or there is no voltage output, then the light may not be on. How to solve it For this kind of problem, the following are the corresponding reference measures.
1. The engine does not start:
First check whether there is fuel in the fuel tank? If not, please add fuel and check whether the engine switch is turned on? If not, turn on the engine switch. Is there enough oil to check? Add oil if it is not enough. Check whether the spark plug is good? If not, clean and adjust the spark plug and reinstall it. If necessary, replace the spark plug.
2. No voltage output:
First check whether the AC circuit breaker is connected? If not, switch on the AC circuit breaker. Check whether the load electrical appliance is faulty. There is a malfunction, replace the device or repair it.
If the above-mentioned inspection and adjustment cannot solve the malfunction problem of the mobile lighting tower, then you need to find a professional maintenance personnel for inspection and repair.